MSA Evolution 5200 HD2 WBK

 

Evolution 5200HD2 TIC

 

SENSOR:
TYPE Uncooled vanadium oxide microbolometer focal plane array detector
ARRAY SIZE 320x240
SPECTRAL RESPONSE 8-14 microns
NETD ≤65mK (in High Sensitivity), ≤240mK (in Low Sensitivity)
DYNAMIC RANGE -40° to 320°F (-40° to 160°C) in High Sensitivity, -40°F to 1040°F, (-40°C to 560°C) in Low Sensitivity
VIDEO STANDARD 16 bit real time analog
FRAME RATE 30 Hz
VIDEO OUTPUT NTSC

MECHANICAL:
DIMENSIONS 10.8'' x 8.1'' x 4.4'' (275 mm x 205 mm x 112 mm)
BASE WEIGHT 45 oz. (2.8 lbs)
MATERIALS Outer case and bumper materials pass simulated NFPA 1981:2002 edition direct flame and heat exposure tests.
OUTER HOUSING Bayer PCPET Makroblend
RUBBER BUMPERS FR neoprene
DISPLAY COVER Heat- and scratch-resistant polycarbonate

ELECTRICAL: 
POWER SUPPLY Supplied by integral battery pack
POWER CONSUMPTION <6 W nominal
VIDEO OUTPUT RS-170 standard SMA connector is included under display for direct connection to remote video source.
DISPLAY 3.5" LCD backlit display

ENVIRONMENTAL
AMBIENT TEMP:

The Evolution 5200 TIC provides the following temperature tolerances:
OPERATING TIME:
80ºC, 176º F > 30 minutes
120ºC, 248º F > 20 minutes
260ºC, 500º F > 8 minutes
-30ºC, -22º F > 40 minutes
-40ºC, -40º F > 25 minutes


WATER/DUST INGRESS: TIC shall resist dust and water and must conform to International Standard CEI IEC 529;
Degrees of Protection Provided by Enclosures (IP Code); IP67 classification.
IMPACT/DROP: Dropped 3 consecutive times onto concrete from 6 ft at any angle with no operational defaults
or physical compromise of outer housing.
VIBRATION: TIC and components housed within carrying case shall be resistant to vibration and must conform to MIL-STD-810E,
Category 3, loose cargo transport.
RFI/EMC: TIC should not interfere with standard firefighter frequency bands at power levels found in hand-held (3-5W) and vehiclemounted
systems (~100W). Communication/electronic devices cannot affect TIC to the point where TIC navigation is compromised
when subjected to RF interference of 80 MHz to 1 GHz at 30V/m. TIC must meet RFI emissions and susceptibility of CE/EN.


OPTICAL: 
LENS 19mm, F1.4
FIELD OF VIEW 34° horizontal, 26° vertical
FOCUS Optimal 3 ft to ∞ (1m to ∞)
DIGITAL ZOOM 2X (optional)

WARNINGS/INDICATORS:
There will be 1 green LED to indicate TIC status, functioning as follows:
GREEN TIC in normal mode and functioning correctly
FLASHING GREEN TIC in standby mode and functioning correctly

BATTERY STATUS:

Total battery capacity will be indicated in viewing area with row of 3 LEDs, functioning as follows:
GREEN Full battery capacity
YELLOW Marginal battery capacity
RED Battery warn – lit for 15 minutes before shutdown
FLASHING RED Battery shutdown – flashes for 60 seconds before shutdown
SHUTTER INDICATOR On-screen indicator appearing as small block in upper left display corner when camera shutters, indicates that area re-scan is necessary.
LOW SENSITIVITY INDICATOR On-screen indicator appearing as letter “L” in lower left screen portion indicates activities when TIC is in Low Sensitivity.

OVER-TEMPERATURE WARNING:

There will be 1 red LED to indicate TIC’s over-temperature status, functioning as follows:
NOT LIT TIC is within operational thermal limits
FLASHING RED TIC has exceeded recommended operational thermal limits


 

 

 

 

 

 

Heiße Herdplatte:

 

 

Gerät ist mittlerweile verkauft. 

 

hbaar - 2012